classic
design
type of operation
nominal diameter
13.0 mm - 50.0 mm
pressure range
0.00 - 12.0 bar (see table)
Kv value
2.0 - 34.6 m³/h
housing material
sealing material
Sealing material, static
Dynamic sealing material
seat seal
screen material
mesh size
opening pressure
Ambient temperature
-10 to +50°C
Temperature Medium
-10 to +80°C
connection
G1, G1 1/2, G1 1/4, G1/2, G2, G3/4, G3/8
Electrical connection
Device socket according to DIN EN 175301-803, type A
connection voltage
voltage tolerance
± 10%
power consumption
see detailed table
duty cycle
100% ED
degree of protection
IP 65 with mounted device socket
installation position
Magnet preferably at the top

Tables/charts

DN
[mm]
Pressure
[bar]
connectionKv value
[m³/h]

weight [kg]

power consumption [W]
130–12G3/82,00,920
130–12G1/22,20,920
200–12G3/46,22,025
250–12G17,11,625
320–12G1 1/416,95,060
400–12G1 1/219,45,060
500–12G234,66,260